Its prime location enjoys panoramic sea views with direct access to the beachfront and secured private rear & basement parking.

It is geared toward progressive businesses that require all the expected luxuries in a modern facility.

With outstanding retail space on the ground floor and supporting mezzanine & basement level storage rooms. The three floors above host single open plan office spaces, unlike any other development seen to-date. All major mechanical facilities are located internally on their very own floor.

It is an ultra – modern business block located on Limassol’s main tourist beachfront artery, which is parallel to the sea.

Foundation and frame work
Surrounding concrete walls (foundations, pillars, beams and slabs) made of reinforced concrete according to the civil engineers static and antiseismic study.

Walls
Concrete and glass (outside walls), bricks (inside walls)

Ceilings
Gipsoplaster ceilings 12mm

Doors and windows
“Alumil” double glazing with 4mm inner glass and 4mm low E outside glass
Outside doors – security doors with complicated locks.
Inside doors – Italian deluxe

Kitchen
Imported kitchens

Floors
Raised floors

Stairs and railings
Italian marble stairs with modern stainless steel rails

Rails
Modern stainless steel

Paints
Three layers of emulsion paint on the inside walls

Sanitary fittings
Porcelain deluxe sanitary ware, chrome tabs “Grohe”. Water mixers and other fixtures are included

Electrical Installation
Concealed circuits and all other installation in compliance with the Electricity authority of Cyprus (EAC) regulations, will comprise of circuits for lights fixtures and power points

Sewerage
Pipe in pipe system. Sewage pumping station and rain water pumping station shall be provided in basement.

Hot - cold water
Every floor shall have individual water meter, water tank on the roof. Pressure systems for hot and cold water installed on the roof.

Heating - cooling provision systems
Provision for heating-cooling system. The actual units are not included.

Elevator
German elevator “Shindler” – corresponds to the European safety regulations

Lighting
Indoor lightings shall provide 500Lux general illumination.
Fluorescent type lightings fittings shall be installed on the false ceiling.
External lighting shall be provided according to Architects requirements to provide functional and decorative illumination.
LED lights (color-changing) may be provided as part of the outdoor and/or indoor decorative illumination.
Power and small power
Every floor shall have a separate electricity meter.
Common areas shall have a separate electricity meter.

External work
Fencing: concrete walls

Parking
Polished concrete floors

Gates
Electrical gates with remote control system

Security system
Fire alarm system: Centralized Fire Alarm System with smoke detectors, alarm bells, break glass points, sirens, strobe lights etc. in all areas.